Sccm powershell return codes To use this script, copy it to a notepad and rename it to ConfigMgAgentRepair. Sep 5, 2016 · This is a guide for Configuration Item and Powershell, if you are new to Configuration Item and baselines i recommend you look at my previous blog post that's more of a overview and in this post i will go more in to depth on Powershell discovery and remediation with String compliance rule. . I tried to execute the script on system using command run as administrator, which executed successfully on the clied machine on the other hand if the script executing via SCCM package it return me this error Mar 16, 2016 · The SCCM Compliance State should say after execution of the ‘Remediation script’: ‘Non-Compliant’ (which is not the case). You do this by exiting the script with a return code. Hi, I'm using the newish "Scripts" feature of SCCM CB to run some PowerShell scripts in bulk on machines. What… May 6, 2018 · With -Command, a script's specific non-zero exit code is always translated to 1, so the specific exit code is lost - see this answer for an overview of exit-code handling in PowerShell. How do I get SCCM to reco Jul 17, 2025 · Applies to: Configuration Manager (current branch) This article is a reference for all of the available variables in alphabetical order. It is possible to use a script for this. ps1 files and not properly reporting exit codes back to ConfigMgr. Feb 18, 2021 · On a Windows Server 2012 R2 Build 9600, I have a Scheduled Task that runs successfully on demand. log file is located in the C:\Windows\ccmsetup\Logs folder on the client computer. Let's say I have a program that I need to uninstall and restart the You could make exit code 1 a success code in the options tab of the task sequence step as a workaround until you figure out how to force the exit code or resolve the issue. ps1". With very few exceptions you should be deploying applications using applications, not packages. One of the benifits is they have various ways to detect if the application is installed. It uses Windows Form controls to do this. Aug 30, 2018 · Describes the ways that SCCM handles reboots for a Package & Program. Jul 26, 2018 · Can you verify via the execution history (manually in regedit or with roger zanders sccm client center whether the return code 3010 is indeed received by the sccm? The problem is, the task sequence always gets return code 0 through the TS engine's command line interpreter. In addition, for other client logs, take a look at the SCCM log files. 1682. It doesn’t seem to be actually running the installations and returning the exit codes. exe which does not necessarily correspond to the return code of the invoked script. I've run it with cmd, with start, by calling dcu-cli directly, and any combination you can think of and it doesn't work. It should be: Program: "cmd. Jul 26, 2018 · On PowerShell 2. Oct 27, 2020 · PENDING Use Powershell to create Application with specific Return Code handling (set 3010 to Success ) pede Oct 27, 2020 1 Apr 28, 2022 · Do you have an execution policy assigned and enforced via policy (Intune or Group Policy)? If so, you can't override this locally. I showed you how the retry schedule looks at the Exit Code / ExitCode to determine whether the app was installed successfully. 1). Try and press Win+R, put in "move" and press enter - that's the interactive equivalent of what your task is failing to do. microsoft. The reason is that MOVE is not a program, but a native command in cmd. exe -DeploymentType Install/Uninstall the Parameter: -AllowRebootPassThru Nov 30, 2020 · Hi Guys I am trying to deploy a PowerShell script using SCCM package and I get the error code 0x1(1) The log states Program failed with error code 1 If i deploy the Jan 23, 2018 · I have a package that points to a Powershell script which runs the installation steps. Oct 29, 2018 · $host. As you can see above, there are also exit codes for soft and hard reboots, and lastly, retry. Everything works fine, but one return code comes back as an… Aug 30, 2018 · Describes the return codes that SCCM understands for Package and Program deployments and shows which codes are classed success, reboot, or retry. exe) which is working fine without any issue when i run manually as admin. As Ryan Ries pointed out, 2147942402 translates to "File not Found" - which is a very appropriate response. Environment]::Exit (<number Anyone know how to return an exit code from a Powershell script so that the status monitoring will read it? Simply using "exit 1" does not seem to be working. exe -ExecutionPolicy Bypass -file "BackupAgent_Install. This won’t let you install anyupdates for Windows or any drivers, and it al… Jun 19, 2023 · I use the program powershell. I am returning custom exit codes (including 0 for success) depending on what happens in the script. Dec 18, 2019 · I can send the different return codes from my Powershell script, but I don't know how I would setup the package to accept multiple return codes and report on it. However, the description shown for the return code you cannot modify Aug 1, 2022 · In one of my earlier blogs, I discussed the IME installation flow and the global retry schedule. You can use these codes to control deployment flow or to understand what occurred. log: Process completed with exit code 3010 Set a global environment variable _SMSTSLastActionRetCode=3010 From BDD. log TSHOST: Script completed with return code 3010 ZTI ERROR - Non Apr 19, 2022 · Passing an exit code 1 or even an exit 0 without any output will flag as an install failure. Aug 29, 2024 · As an SCCM administrator, it's important to learn how to troubleshoot an SCCM client with SCCM client installation error. 0 and also perhaps 3. However what I have found is that the task sequence fails on the LGPO step due to the application throwing an error code. Seems pointless tho when its so easy to set via GPO. log file contains the reasons why the task sequence failed along with additional errors. I have actually looked into this before and haven't been able to find a Lenovo BIOS update that plays nicely with ConfigMgr exit codes, so it's possible that you'd have to use a wrapper script such as PSADT to catch custom codes and pass a different code back to the client agent. My package will return 3010 - reboot required when the script is finished. May 12, 2017 · While the script when running it from a powershell window, I still get an error code in SSIS. The line CcmSetup is exiting with return code 0 Task sequence error : PowerShell command line returned code 128 : r/SCCM r/SCCM Current search is within r/SCCM Remove r/SCCM filter and expand search to all of Reddit Sep 23, 2019 · Veeam Community discussions and solutions for: Backup Script error code - 196608 of PowerShell I packaged the powershell script into an intunewin file and made a detection script that checks the device name to make sure it no longer fits the automatic naming scheme from the deployment profile, then exits with a code 0 if it worked. This can be changed within Intune when you are deploying a Win32 application. exe -executionpolicy bypass -file \sccm_server\share\script_file. But It does work with version Dec 10, 2015 · I have the following code, but I need to extract the “return code” string as well as whatever numerical value is there, either a “0”, or a 1", etc. When using " [System. exe" Arguments: "/c move C:\Windows\Temp\*. which makes sense because from SCCM's point of view, it did fail. I've been wondering about this myself. Use the browser Find function (typically CTRL + F) to find a specific variable. For example: cmd /c exit 1 (Of course, you must also ensure the "Continue on error" check box for the task sequence step is unchecked. Hi All, I have a deployment for a new software using Powershell App Deployment Toolkit. SCCM Powershell cmdlet - Return Codes Is there a way to use the SCCM powershell cmdlets to specify custom return / exit codes when creating an Application? I'm looking at Set-CMScriptDeploymentType and Add-CMScriptDeploymentType but not finding anything about how to specify this. Search for PowerShell exit code on the web and you will get long discussions on the ins and outs of the return code of powershell. Jul 13, 2018 · Below is a PowerShell script that I use to add a digital signature to files. Jul 18, 2025 · What this means is creating a separate folder for it in SCCM and then running a PowerShell script to move the objects into the folder and remove it from Distribution Points. The article on task sequence steps includes the list of variables specific to each step. hi, is there any way to trigger computer reboot with SCCM toast notification from command line? I know method with return codes in "applications"… Jan 5, 2016 · I have a script that I am pushing via SCCM. Jun 9, 2025 · SCCM did not install properly on a newly imaged system and need to reinstall SCCM on a Windows 11 workstation. Sep 2, 2021 · When setting a custom Fast Retry return code for an application that is deployed as available or required, specifically when using PSADT, does that mean the failed Feb 1, 2025 · If you receive error code 0xFFFD0000 while using the Task Scheduler to schedule running of a Powershell Script, then this post will help you fix the problem. exe has worked when not selecting the "Run whether logged on or not". It returns the proper exit code - From smsts. The below PowerShell scri… 3 days ago · C:\Windows\CCM>ccmrepair. (We actually were running two unique scripts from unique UNC paths) Suddenly, the Scheduled task ends with: Task Scheduler successfully completed task "\Check SCCM Client Health" , instance " {f82bb62c-65e3-408c-8c26-2bd06c663a34}" , action "powershell. Dec 15, 2021 · You can run SCCM Powershell cmdlet and scripts from the SCCM console or from a Windows PowerShell session. The variable notes if it's specific to particular step. SCCM - Assets & Compliance… Feb 22, 2022 · I am using a simple script (a batch file) to install software (Cisco AMP Endpoints Connector). Goal 2: Trigger via PowerShell from the local client without reaching back to the Server (Completely offline) Basically to replicate this experience, but locally via PowerShell: Dec 16, 2024 · Applies to: Configuration Manager (current branch) Configuration Manager has an integrated ability to run PowerShell scripts. The script fails and returns 1; however, SCCM shows the deployment was successful. Jul 3, 2024 · For more information, see Configuration Manager SDK. That post is still being read pretty well. For more information, see getting started. I've removed some of the enhancements to my Rename-Computer script to demonstrate Exit codes. Can I fix this by adding an exit code? so that it just always exits with a 0? Exit Codes PSAppDeployToolkit uses pre-defined exit codes to indicate whether a deployment succeeds or fails. If that works, then you can also use Invoke-Command -ComputerName <target> -FilePath <script>. Feb 21, 2018 · During a recent ConfigMgr side by side migration project I was asked to provide a reliable way to return AD Site and SCCM site code information for each computer in an OU. It also creates a detection method to be used by ConfigMgr to determine compliance: two registry values with the install date and the HPIA exit code; the detection method is a Powershell script that returns compliant if the install date is no more that 30 days old and the last exit code is either 0, 3010 or 257. The scripts simplify building custom tools to administer software and let you accomplish mundane tasks quickly, allowing you to get large jobs Aug 31, 2019 · SCCM client not reflecting in sccm console after exit code 0, checked all ports working fine need some suggestions Feb 5, 2020 · After creating a new PowerShell task and copying some parameters from my “old” task i get this strange error code. Exit Codes PSAppDeployToolkit uses pre-defined Exit Codes to indicate the success or failure of a deployment and can be used to control the flow of your deployment logic, or just to understand what happened during a deployment. Aug 21, 2024 · Repair SCCM Client Agent PowerShell Script to Remotely Repair SCCM Client Using the below PowerShell script, you can remotely repair SCCM client. Jan 25, 2019 · On the machines that are detecting improperly, is there a PowerShell profile that's writing to the host. Is is possible to have Config Manager understand these custom exit codes for the… Jan 30, 2023 · I have the the following question (SCCM/MECM version 2207). To do this in powershell you need to use the Exit keyword. From the SCCM console, you can: edit your scripts, import existing scripts, approved or deny scripts, run scripts on specific collections and examine scripts results. There is a known behavior with SCCM versions prior to 1810 where detection methods are run without using the -noprofile argument so if the machine (or user) has a powershell profile that writes something to the host its picked up as a detection. ) Indeed, you could replace the 1 above with any other number if you want to use different exit codes to reflect Dec 18, 2019 · I can send the different return codes from my Powershell script, but I don't know how I would setup the package to accept multiple return codes and report on it. 1. Feb 4, 2021 · In this blog post, I explain how to create an SCCM detection method, which uses Powershell to parse a file and detect content. But by using Start-Process and forcing it to wait for the exit code using passthru, it properly returns the exit code. Aug 26, 2015 · There is a known problem with powershell exit codes (see the end of this answer) that can manifest when using powershell installation scripts with SCCM. If you provide client installation parameters on the command line, they modify the installation behavior. nl) I decided to remove Sep 28, 2012 · When you run a script in your deployments, it's good practice to let MDT/SCCM know how the script has ended. I have no idea how to do this. SetShouldExit (0) #where 0 is the number you want to return Poking around I found (scripting - How to get SCCM to recognize return codes from Powershell script completion? - Server Fault) [System. In case you notice CcmSetup is exiting with return code 7 then you must reboot your computer to complete the client agent installation. You could add that to the return code properties on your Win32 app in Intune and maybe set it to "Retry" but that in my mind would open up the possibility for the deferral time in PSADT being less then the retry time from Intune which could cause some confusion. exe and as arguments -File "L: [path]\test. ps1" Same script works fine manually on PC. The script return exit code 3010 when a reboot is required. Is there anyway I can have SCCM look at that exit code and basically ignore it? Aug 5, 2019 · Command line: Powershell. Use the following table to determine how May 29, 2020 · Goal 1: Trigger a Restart of a computer, which will use the Configuration Manager Dialogs Boxes and so the CM Client is aware of the Restart and not start any jobs. All PowerShell scripts should be signed and you should absolutely be enforcing the All Signed execution policy as well as PowerShell constrained mode. Is there anyway I can have SCCM look at that exit code and basically ignore it? Jan 22, 2019 · If you’re on an older version, try running your scripts as script installers with the command line as so: Powershell. exe – Issue Triggers using WMI SCCM – Windows Upgrade Return Codes SCCM – Package is showing Content Distribution ‘In Progress’ SCCM – Rebuild WMI SCCM – Launch Control Panel Applet SCCM – Install Distribution Point on Workgroup Computer SCCM – How to Rebuild NAL SCCM – PowerShell – Modify ADR’s Deadline Time Aug 14, 2023 · The PowerShell script can be used to schedule sccm client reboot through application deployment. I need it to run every hour every day. Use the information in this article to assist with troubleshooting application installation errors. 19041. However in any case, having SCCM try and either import our config XML, or run any "/configure" command fails with return code 2. For more information, see Using Jun 15, 2016 · There have been a lot of discussion how to write a proper PowerShell detection method and how to tell Configuration Manager if the application was detected. Dec 9, 2014 · I'm currently creating a package for SCCM that is wrapped using PowerShell. Jan 19, 2018 · I am trying to schedule a job to run a batch file with Windows 10 Task Scheduler, but it results in return code 2147942401. Jul 7, 2017 · 0x8007000d means that there is a file that is needed by Windows Update, but that file is either damaged or missing. Hi This involves a bit of powershell knowledge here which I am pretty crap at hence why its probably not working I have a configuration baseline set up with a powershell script The script does a whole bunch of things ( got this from the internet ) and then spits out errorcodes and an output based on what it did I added my own small bit of code to tell the configuration item if it worked or not SCCM (System Center Configuration Manager) PowerShell is a powerful tool that allows administrators to automate and manage configurations within the SCCM environment through scripting. This will determine how your task sequence proceeds. nl) Trigger IME to retry to install a failed Win32app | Intune (call4cloud. I have a Powershell script that runs during my task sequence that I have exit 3010 to return that code for the task sequence to initiate a reboot, but it's not working. exe explicitly. 2. If you don’t want stage contents to Configuration Manager client cache (if contents are staged to Task sequence working directory, content folder is automatically cleaned up after task finished), then don’t use any step that will use the same package, or use variable instead. In PowerShell, a return code (also known as exit code) indicates whether a command was executed successfully or encountered an error, with a return value of `0` typically signifying success. The behaviour depends on the Program configuration, deployment method and return code. This can be useful to run a script quickly without the burden of creating a package or an application. Installers signal failure or the need to reboot using exit codes. Based on the interest of that post, and the intro… If you must go down this path, keep in mind it runs as System account when running in SCCM, if you have changed so that this runs as the user, you might have a bunch of other options to test such as Run as interactive, run with syswow64 cmd. In order for exit codes to get to the ConfigMgr client you need to ensure that your install and uninstall scripts are structured correctly. However if i execute via SCCM Nov 11, 2019 · A long time ago, I did a post about Working with the restart behavior of Applications in ConfigMgr 2012. Nothing we can do about it, it's vendor default (Comsol 6. Environment]::Exit (0) Instead of mindlessly stealing code I would like to understand why I should use what I am using. For more general information, see Deployment type Return Codes. Things I have tried: SMSTSPostAction - "CMD /C EXIT /B 3010" Apr 11, 2023 · Applies to: Configuration Manager (current branch) Use the CCMSetup. My code Jul 10, 2020 · Categorie ConfigMgr, SCCM, windows updates, Configuration Manager, Center Configuration Manager, SCCM 2012, System Center 2012 Configuration Manager, SCCM Client Agents, SCCM 2012 R2, ConfigMgr Current Branch, MSI Return Codes Jan 22, 2019 · If you’re on an older version, try running your scripts as script installers with the command line as so: Powershell. "Run command line" and "run powershell script" steps don't seem to care what the script outputs - they just return 0 because the script ran. If you're really handy and want to go down the rabbit hole, you could determine the spawned process and actually wait for it to complete rather First, are you talking about actual package or application objects within ConfigMgr. 0 at least, there is a bug with the -File parameter of PowerShell so that it does not pass the exit code back to the calling process. Troubleshooting failed Intune Win32 Apps installation | IME (call4cloud. When using "exit <number>", this window reports that all instances of the script returned an exit code of 0. The code is naturally in the You could also change the script to return the exit code for 'The computer needs a reboot' which is 3010. I know that the application setup will return an exitcode 4 (fail) if the license server is not reachable during install time. I'm still looking for a way to still use Powershell script as an Application in MDT keeping the return code working all the way up but for the meantime I have a suitable workaround Dec 12, 2023 · Based on the error message you provided, this error code 0x00000001 indicates that the task sequence failed to execute. My script has various exit codes, but I can't get the Script Status Monitoring window that tracks progress to recognize these. Here’s a simple code snippet to get the list of all collections in SCCM using PowerShell: Get-CMCollection | Select-Object Name, CollectionID Understanding PowerShell for SCCM Why use PowerShell with SCCM Then fails with exit code 1 Test the script by running it manually on my test computer with psexec as system ( sccm runs the application as system) and it installs without issue ) Next thing I tried to do is just use a cmd script to install through sccm and that installed fine to So its something to do with SCCM and the powershell script. exe command to install the Configuration Manager client. Sep 8, 2021 · Since SCCM 1706, you can run and deploy Powershell scripts from the SCCM console basically in real-time. To workaround the problem, I take two measures: I always have SCCM invoke a batch file which runs the powershell script by invoking powershell. The script works when I run it manually (the software installs), but when I create an install package in Endpoint Config Manager (SCCM) to use that script, I… Apr 8, 2020 · I have a installaer package (mySoftware. Simply having it return "Installed", or any non empty value, if the package is found, will result in SCCM thinking it's installed. All Signed (System Center 2012 R2 Configuration Manager and System Center 2012 Configuration Manager SP1 only): The Configuration Manager client runs scripts only if they are signed by a trusted publisher. Sep 2, 2020 · Hi, I am hoping someone can shed some light on what seems an incredibly simple thing but is driving me mad :-) I have a PoSH script which I am delivering through InTune as kind of a 'First Setup' script for an endpoint coming in via AutoPilot. Starting in version 2107, use this cmdlet to get the list of return codes from the specified application deployment type. It does a… Oct 20, 2015 · ConfigMgr needs to see exit codes from your installation and uninstallation scripts in order to do the right thing. A correct argument for a PowerShell script should look like this: -NoProfile -ExecutionPolicy Bypass -File "D:\Scripts\PowerShell\dev2. Starting in version 2107, use this cmdlet to delete return codes from the specified application deployment type. Jul 23, 2018 · SOLVED: scheduled task completes with return code 2147942401 Software & Applications question general-windows billleuze2 (TeraBil) July 23, 2018, 2:53pm Another alternative to adding the 259 result code to the deployment type is to script the install. The ccmsetup. execmgr 10/1/2022 9:16:09 PM 2000 (0x07D0) Any idea why this failure? Thanks This self-answered question tries to address two distinct aspects of dealing with process exit codes in PowerShell: In PowerShell code, how can you query the exit code set by an external process (a Feb 17, 2013 · This week I will do a small post about working with the restart behavior of installations in combination with the Application Model in ConfigMgr 2012. I For anyone who had the same problem/question, use the Exit-Script 3010 function at the end of install/uninstall in the script and in the SCCM Deployment Type add to Deploy-Application. Run Configuration Manager cmdlets and scripts in PowerShell from the Configuration Manager console or from a Windows PowerShell session. Jun 4, 2016 · Running the code from the ISE or the Powershell command line code works every time. execmgr 10/1/2022 9:16:09 PM 2000 (0x07D0) Not RS3+, this device is SCCM managed. Feb 22, 2023 · Applications can be installed on clients by creating deployments from the Configuration Manager console or by targeting applications to tenant attached devices from the Microsoft Intune admin center. The log file basically just says it’s doing everything, but doesn’t return an exit code for anything and isn’t behaving like it should (using passthru to show exit code and all installs appear to be failing). This script accepts two parameters: the file name to be signed and the location of the certificate store, current user or local machine. This section contains the help articles for the Configuration Manager cmdlets. This script is useful when you want to repair ConfigMgr client on a computer located in a remote site. - PowerShell Discovery script: Sep 20, 2017 · SCCM 2012 R2 introduced applications. I have a button on the form which should terminate the script with a code so I can inspect the code on later task sequence steps. Starting in version 2107, use this cmdlet to get the list of return codes from the specified application deployment type. In the script, trigger the install, wait (sleep) long enough that the spawned process actually completes, and then return the exit code back to SCCM. What we can do is give feedback to the user and feedback in the log files about that exitcode 4. The meaning of return codes for Packages and Programs is defined in the SCCM site control file. Sep 20, 2017 · Stage contents to Configuration Manager client cache. Nov 25, 2022 · Hi @FrancK , 1, About powershell script result and detect method result, please refer to following links: Create applications - Configuration Manager | Microsoft Learn 2, Besides, here is a similar case for your reference: SCCM Application's script (powershell) detection method not working (microsoft. com) Reference link: SCCM PowerShell Script Detection Method - SCCMOG - Deployment Blog Oct 3, 2022 · The exit code is -196608, the execution status is FailureNonRetry execmgr 10/1/2022 9:16:09 PM 2000 (0x07D0) This machine is not a workstation, returning false for MDMIsExternallyManaged. Expected behavior vagrant up should have started successfully, as it has for a long time before t Upon a fresh reboot and logon, the user will go back to SC and see the task sequence as "failed . Feb 9, 2023 · Hi, I have a PowerShell script that does some stuff on devices. ps1 Replace the file path with the correct info for your script and if any of it contains white space enclose the path in quotes. exe instead, running with powershell instead, etc etc. They differ from packages in that they are much more flexible. In previous versions there was sometimes a need to use a batch file to catch some weird installation return codes. But i am getting exit code 3010,1641 when i install the package via SCCM. The nice thing about ConfigMgr 2012 is that it gives… Oct 9, 2020 · You might also consider using PowerShell remoting if it's available on the target machines instead of psexec. Note Run Configuration Manager cmdlets from the Configuration Manager site drive, for example PS XYZ:\\&gt;. log. Aug 13, 2021 · Here I am looking for a while, a way to add a return code to the list already present in SCCM (the code in red present in the screenshot) I would like SCCM to be able to add it automatically every time I create an application. These are called Detection Methods. You can configure how ConfigMgr interprets the exit code in terms of success, failure, need reboot. The path is correct, and just using powershell. com/en-us/mem/configmgr/apps/get-started/creating-windows-applications#bkmk_tsdt trying to figure out how to exit task sequence with 3010 exit code so application would request device restart. 1, (actually noticed the issue on 2. It basically comes down to Powershell not functioning properly when executing *. PowerShell has the benefit of creating sophisticated, automated scripts that are understood and shared with a larger community. SCCM – wmic. When I add it as a RunPowerShell task sequence step (MDT 2012/2013 and SCCM 2012 all tried) the task sequence fails with From the PSADT documentation the deferral return code is 60012. exe Repairing product {88B420C9-C484-4E20-8D02-C25243A36B80}… Done. If you provide client installation properties on the command line, they modify the initial configuration of the installed client agent. Here is the powershell script I am running: Dec 11, 2020 · Get to the root of error 1612 and learn how to correct broken app sources in deployments. exe" with return code Sep 17, 2024 · What are exit codes? When you've deployed an application with Intune and it's been successfully installed, it will return an exit code of 0 by default. Apr 2, 2017 · Hi, I am working on a new script that runs during our SCCM OSD to collect the computer name. Also, even if you don't, bypassing the execution policy is a terrible idea and practice. One possible cause of this error is an issue with the MDT Toolkit package. The batch file is on remote location so I am giving the absolute path "\\\\ Feb 13, 2020 · Calling the script from the MDT Run Powershell Script everything works as expected. ps1" Click Ok (twice) and re-run the scheduled task to see if the problem is solved. Jun 2, 2021 · This post describes the return codes that SCCM understands for Package and Program deployments and shows which codes are classed success, reboot, or retry. (If I'm wrong about thinking you want SCCM to check for the update, and if not found, install something, then remove the "Installed" and put it in an else {} statement) Apr 11, 2017 · Verify that the path is to the PowerShell script is correct and paste the correct argument back into the scheduled task. 0 and upgraded in hope for a quick fix) Host operating system Windows 10. You can monitor the SCCM client agent repair process by reviewing the ccmsetup. ps1. Jan 6, 2025 · This blog post aims to present all our SCCM PowerShell scripts simply for you to see if any scripts may help you. Beyond that, the answer is basically no. To cause a task sequence to fail, you can use a "Run Command Line" task sequence step to execute a command that returns a non-zero 1 exit code. foo E:\Foo_blah_blah Mar 28, 2022 · Hi Team, I need help to investigate the issue with batch script installation which I installing on the client machines through SCCM Package. When you run Configuration Manager cmdlets by using the Configuration Manager console, your session automatically runs in the context of the site. For some reason, it is not working properly. Unlike standard May 5, 2021 · Client prerequisites Updates and fixes for the Configuration Manager client The line ccmsetup is exiting with return code 0 confirms the client agent has been reinstalled successfully. Nov 22, 2018 · Vagrant version Vagrant 2. Feb 21, 2024 · For example, when a SCCM task sequence fails with error code 0x80070002, the smsts. Trouble is that everything I have tried so far to exit with a code causes and exception to be thrown. Jan 30, 2023 · I know that the application setup will return an exitcode 4 (fail) if the license server is not reachable during install time. But there are some specific rules on what is returned via the various output streams. SCCM has new option to run Task Sequences as Application deployment type: https://docs. There are… Up until the end of December, we were running a powershell script via Scheduled task from a UNC path, as SYSTEM. This post explains how a PowerShell detection method for sccm works and what it should return if the applications is detected as installed. But upon checking the execution history of the machine where I assigned the package, 3010 exit code was recognized as Exit Code Failure. Jul 6, 2022 · Hi all, I've noticed that a scheduled task running a powershell script doesn't work on version 5. The script can also remove any deployments and update the Comment/Description with “Containment <date>”. To do that, run powershell locally and see if you can connect: Enter-PSSession -ComputerName <target computer>. The wrapper works as intented. if I change it to &quot;Run Hourly, Every Day&quot;, it fail Master the art of the sccm powershell detection method with this concise guide, simplifying your workflow for efficient system management. This restriction applies independently from the current Windows PowerShell configuration on the client computer. Important Note: Detection scripts ONLY work in the System context so if detecting at the user level, you need to enumerate the logged in user. I'd love to be able to provide a hash table of custom exit codes. hjufobs bveihm ncdtqtcq mmp yxv ngskk fuao helqjju jizl pnccql cuq vudkne suiiie uxmvtyl uyl